It was developed by an ABAA committee that included testing agencies, envelope consultants, air barrier systems manufacturers, architects, engineers, test and balance contractors, and the manufacturers of blower door testing equipment over the course of three years, including two rounds of voting and two rounds of external review.
Once the energy auditor arrives, it takes between 10 and 20 minutes to install the blower door inside an existing door frame, an additional 10 to 15 minutes to prep the house for the test, and
Elevate your HVAC testing with the TEC Combo by Vent Cap Systems—your all-in-one solution for blower door and duct blaster tests. Powered by dual DG-1000 gauges and our 21-piece Total Home Pack, achieve unrivaled efficiency and accuracy in sealing and testing. Invest in the ultimate toolkit for superior performance—available exclusively at
The Superior method of generating smoke by chemical reaction eliminates costly equipment and time consuming operations in pinpointing HVAC leaks. Detecting HVAC Leaks. Smoke testing has eliminated the need for tedious and time consuming soaping techniques. When smoke testing HVAC systems, smoke is traditionally introduced through the system intake.

What minimum specs would an old furnace fan (or new Harbor Freight fan) need to have to do decent blower door directed air sealing work on an old leaky house? (Not necessarily for a DIY blower door scoring). Say, for example, a 2000 sq ft house with a blower door score of 2500 CFM at 50 Pa.

For more information on blower door rental equipment or pressure testing, please call or email us at 608-467-2008 or info@a-aexteriors.com. Easy commercial blower door equipment rentals for testing agencies. Rent one of the largest blower door fans in the US. We ship throughout the United States! Some raters prefer to do this test with the fans reversed so that they pressurize the house and ducts to 25 pascals rather than depressurizing the house to -25 pascals. How to Test Duct Leakage to the Outdoors. Install a blower door in an exterior door that opens to a central location in the home. Though the building leakage curve can be estimated using a single-point blower door test, the curve is more reliable when a multi-point test is used. The test performed in the example above was an ASTM E779 multi-point test. The leakage rate at 60 pascals was 806 cfm, and at 18 pascals, 339 cfm. Follow the step-by-step instructions below to design your blower door test results form: Select the document you want to sign and click Upload. Choose My Signature. Decide on what kind of signature to create. There are three variants; a typed, drawn or uploaded signature. Create your signature and click Ok. Press Done. 0ISJ.